TESTOMAT 2000® ANALYZERS
More than an automatic in-line analyzer for controlling water hardness
The TESTOMAT 2000® is an instrument for online measurement and control of water quality in treatment facilities. It can be used in all areas where water hardness needs to be checked. As for example for steam generators in boiler rooms, for water treatment installations by softening and / or reverse osmosis or for drinking water installations.
The TESTOMAT 2000® is TUV WÜ 100 certified within the scope of boiler water monitoring, in accordance with standard TRD604-part 2. Its specific design now allows it to measure many other parameters in water, such as chlorine, iron, sulphite and many others, alone or in combination.
The use of TESTOMAT 2000®, combined with SOFTMASTER® and ECOCONTROL®, allows to produce less wastewater, to use less salt and to reduce the costs of energy consumption. Its fields of application are particularly in the food industry, the chemical and pharmaceutical industry, in the medical sector and many others (see our catalog).
Thanks to improved accuracy and dissolution, combined with constantly improved evaluation features, the current generation helps to ensure optimum water quality.
Overview of the main models in the range
Model | Parameter | Measuring range | Additional function |
---|---|---|---|
Testomat ECO® | Water hardness (TH) | 0.09 – 44.8 ° f (TH) | Integrated analog output |
Testomat 2000® | Water hardness (TH) Carbonate hardness (TAC) P-value (TAS) M-value (TAF) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) 1 – 15 mmol / l 0.05 – 0.50 mmol / l |
1 or 2 measuring points (same range) Auxiliary program History of faults |
Testomat 2000® CAL | Water hardness (TH) Carbonate hardness (TAC) P-value (TAS) M-value (TAF) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) 1 – 15 mmol / l 0.05 – 0.50 mmol / l |
Calibration function |
Testomat 2000® V | Water hardness (TH) Carbonate hardness (TAC) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) |
Hard water / soft water regulation |
Testomat 2000® Self Clean | Water hardness (TH) Carbonate hardness (TAC) P-value (TAS) M-value (TAF) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) 1 – 15 mmol / l 0.05 – 0.50 mmol / l |
Automatic cleaning function |
Testomat 2000® Antox | Water hardness (TH) Carbonate hardness (TAC) P-value (TAS) M-value (TAF) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) 1 – 15 mmol / l 0.05 – 0.50 mmol / l |
Reduction of high chlorine or H2O2 content |
Testomat 2000® DUO | Water hardness (TH) Carbonate hardness (TAC) P-value (TAS) M-value (TAF) |
0.09 – 44.8 ° f (TH) 0.90 – 35.8 ° f (TAC) 1 – 15 mmol / l 0.05 – 0.50 mmol / l |
1 or 2 measuring points (different range and / or parameter) |
Testomat 2000® CLF | Free chlorine | 0 – 2.50 mg / l | 1 or 2 measuring points |
Testomat 2000® CLT | Total chlorine | 0 – 2.50 mg / l | 1 or 2 measuring points |
Testomat 2000® CLO2 | Chlorine dioxide | 0 – 2 mg / l | 1 or 2 measuring points |
Testomat 2000® THCL | Hardness Total chlorine |
0.45 – 4.48 ° f (TH) 0 – 2.50 mg / l |
Combined TH + CL |
Testomat 2000® Br | Bromine – Br2 | 0 – 2.23 mg / l | 1 or 2 measuring points |
Testomat 2000® CrVI | Chromate (CrO42-) Chromium VI (CrVI) |
0 – 2.0 mg / l (Chromat) 0 – 1.0 mg / l (Chromium) |
1 or 2 measuring points |
Testomat 2000® Fe | Iron (Fe II – Fe III) | 0 – 1.0 mg / l | 1 or 2 measuring points |
Testomat 2000® Polymer | Polyacrylate dosage | 0 – 50.0 mgL | Adaptable to the customer |
Testomat 2000® SO3 | Sulphite (SO32-) | 0 – 10 mg / l | 1 or 2 measuring points |
(other models available – consult our catalog)
For more technical details or to obtain the complete documentation of a model, please send us your request via our contact form.
SOFTMASTER® MMP / ROE CONTROLLERS
Control units for water treatment
The SOFTMASTER® unit combines control with analysis functions. It is designed to operate and control water treatment and dosing installations.
- SOFTMASTER® MMP is used to control simplex, alternating duplex, parallel duplex or serial duplex softeners, for fully automatic regeneration depending on the quantity, time and / or quality of the water in the treatment facilities.
- The SOFTMASTER® ROE is a control device for the fully automatic operation of reverse osmosis water treatment plants, integrating online conductivity measurement.
The technology of these controllers offers a flexible system allowing standard operations as well as specific applications.
All our SOFTMASTER MMP control units are connected to many softener valves, such as those from Fleck, Autotrol, Siata, etc… Do not hesitate to ask us for connection plans.
Overview of the main models in the range
Model | Application | Mode |
---|---|---|
Softmaster® MMP Compact | Softener | Simplex Alternating duplex |
Softmaster® MMP1 | Softener | Simplex Alternating duplex |
Softmaster® MMP2 | Softener | Simplex Alternating duplex |
Softmaster® ROE Compact | Reverse osmosis | 1 pump |
Softmaster® ROE1 | Reverse osmosis | 1 pump |
Softmaster® ROE2 | Reverse osmosis | 2 pumps |
(other models available – consult our catalog)
For more technical details or to obtain the complete documentation of a model, please send us your request via our contact form.
ECOCONTROL® EC DOS DESALT BOX
Process measuring device
The ECOCONTROL® EC Dos Desalt can be used either as a device for measuring conductivity or dry TDS filter residues, or as a control device for cooling circuits.
As a measuring device, it is used to read the conductivity of the water and to control solenoid valves if the programmed limit values are exceeded. Its field of application is the monitoring and regulation of industrial process water circuits.
As a control and desalination device, it allows the conductivity of the water to be measured and thus to control solenoid valves, motorized valves as well as the dosage of biocides according to the specific needs of the installation. Its fields of application are the monitoring and regulation of industrial process water circuits, the monitoring of cooling towers and boiler feed water.
For economical and trouble-free operation, it is essential to treat the water and monitor the water circuits with on-line measuring devices suitable for this purpose.
Overview of the main models in the range
Model | Function |
---|---|
ECOCONTROL® EC Dos Desalt | Conductivity meter, TDS, dosage and desalination |
ECOCONTROL® pH | PH value meter |
For more technical details or to obtain the complete documentation of a model, please send us your request via our contact form.
TESTOMAT 2000® INDICATORS / REAGENTS
REAGENTS
The Testomat 2000® device is designed for the field of water treatment (osmosis system, softening, drinking water, etc.). The inlet water must be clear, colorless and free from suspended particles. The parameter to be measured and the related measuring range are determined by the choice of indicator and by appropriate programming carried out by the user.
Range overview / Measuring ranges
Type | Parameter | ° dH | ° f | ppm CaCO3 | mmol / l | mg / l (ppm) |
TH 2005 | Water hardness | 0.05 – 0.50 | 0.09 – 0.89 | 0.89 – 8.93 | 0.01 – 0.09 | – |
TH 2025 | Water hardness | 0.25 – 2.50 | 0.45 – 4.48 | 4.48 – 44.8 | 0.04 – 0.45 | – |
TH 2100 | Water hardness | 1.00 – 10.00 | 1.79 – 17.9 | 17.9 – 179 | 0.18 – 1.79 | – |
TH 2250 | Water hardness | 2.50 – 25.00 | 4.48 – 44.8 | 44.8 – 448 | 0.45 – 4.48 | – |
TC 2050 | Carbonate hardness | 0.50 – 5.00 | 0.90 – 8.96 | 8.9 – 89.5 | 0.18 – 1.79 | – |
TC 2100 | Carbonate hardness | 1.00 – 20.00 | 1.79 – 35.8 | 18 – 358 | 0.36 – 7.14 | – |
TM 2005 | * | – | 0.05 – 0.50 | – | ||
TP 2010 | TAS | – | – | – | 1.1 1.5 | – |
TP 2100 | * | – | – | – | * | – |
CL 2250 A | Free + total chlorine | – | – | – | – | 0 – 2.50 |
CL 2250 B | Free + total chlorine | – | – | – | – | 0 – 2.50 |
CL 2250 C | Total chlorine | – | – | – | – | 0 – 2.50 |
CL O2 – A | Chlorine dioxide | – | – | – | – | 0 – 4.70 |
CL O2 – B | Chlorine dioxide | – | – | – | – | 0 – 4.70 |
CrVI 2100 A | Chromate / Chrome | – | – | – | – | 0 – 2.0 |
CrVI 2100 B | Chromate / Chrome | – | – | – | – | 0 – 2.0 |
Fe 2005 A | Dissolved iron (II) and (III) | – | – | – | – | 0 – 1.0 |
Fe 2500 B | Dissolved iron (II) and (III) | – | – | – | – | 0 – 1.0 |
SO3 – A | Sulphite | – | – | – | – | 0 – 20 |
SO3 – B | Sulphite | – | – | – | – | 0 – 20 |
Self clean | Cleaning solution | – | – | – | – | – |
Sol. ANTOX | Anti oxidant | – | – | – | – | – |
Br2 – A | Bromine | – | – | – | – | 0 – 5.6 |
Br2 – B | Bromine | – | – | – | – | 0 – 5.6 |
Please observe the safety instructions for handling reagents, chemicals and cleaning agents. Observe the corresponding safety data sheet (available on request).
CHEMICALS AND MOBILE ANALYSIS KITS
DUROVAL – DUROGNOST – TESTOVAL
Reliable and economical processes are the foundation of a detailed water analysis. The processes developed by HEYL make it possible to perform analyzes without prior knowledge of chemistry and without specific laboratory equipment.
MOBILE – SECURE – FAST – ECONOMICAL
TESTOVAL® and DUROVAL® reagents can be used for all applications in the field of industrial water treatment, swimming pools, potable or non-potable water and water in dialysis departments and in hospitals.
We offer all the reagents necessary for the examination of boiler water in an analysis case. This complete portable laboratory is used to perform all regulatory examinations in the field of boiler water and boiler feed.
Likewise, we individually put together the sets needed for other mobile water analyzes, such as monitoring reverse osmosis installations, aquarium keeping and various wastewater checks. Thus, the user can carry out his own checks on site.
Our range consists of:
DUROGNOST® limit value kits
Quick dosing kits for water hardness, set to limit values.
DUROVAL® Drop rapid dosing sets
Compléxometry titration kits for the analysis of water hardness.
1 drop = 1 ° f (TH)
DUROVAL® AF / BF / TF Rapid Dosing Kits
Compléxometry titration kits for the analysis of water hardness, carbonate hardness, chlorides, etc. by measuring range.
TESTOVAL® colorimetric analysis kits
Color comparison kits for the concentration ranges of parameters such as aluminum (Al), iron (Fe II – Fe III), copper (Cu), chlorine (according to the DPD method), nitrates (NO3 -), and many others.
For more details, please see our catalog.